O-ring,-018 200905
Product Name: O-Ring, -018 (Part No. 200905)
Description:
This component is an O-ring seal, AS568 standard size -018, specifically designed for high-pressure waterjet cutting systems . It is a precision-molded elastomeric sealing ring manufactured from premium-grade materials such as Buna-N (Nitrile), Viton (FKM), or EPDM, chosen for their excellent resistance to water, hydraulic fluids, and extreme mechanical stress .
The O-ring functions as a critical static or dynamic sealing component within the waterjet intensifier pump assembly, providing a leak-proof barrier between mating surfaces such as the check valve body, cylinder liner, outlet manifold, and other hydraulic interfaces . It is designed to maintain sealing integrity under continuous ultra-high pressure operation up to 60,000 PSI (approximately 4,137 bar) and can withstand temperatures ranging from -30°C to +200°C depending on material selection .
This O-ring is an OEM direct replacement part compatible with OMAX, AccuStream, KMT, FLOW, BFT, KUNDA, and WSI waterjet systems . It ensures reliable sealing compression, pressure retention, and hydraulic integrity even under extreme pressure fluctuations and abrasive environmental conditions .
Applications:
Provides static sealing in check valve bodies, cylinder liners, and outlet manifolds of waterjet intensifier pumps
Used as a sealing component within the high-pressure water circuit and hydraulic system
Suitable for ultra-high pressure waterjet systems operating at 60,000 PSI and above
Compatible with OMAX, AccuStream, KMT, FLOW, BFT, KUNDA, and WSI waterjet systems
Used extensively in metal fabrication, stone cutting, ceramic machining, and composite processing
Features:
Standard AS568 Size -018: Conforms to industry-standard dimensions for precise, reliable fitment in designated seal grooves
Premium Material Options: Available in Buna-N, Viton (FKM), or EPDM for excellent chemical compatibility and compression set stability
High-Pressure Rating: Engineered for continuous operation at 60,000+ PSI (4,100+ bar)
Wide Temperature Range: Performs reliably from -30°C to +200°C depending on material selection
Precision-Molded Dimensions: Uniform cross-section and tight dimensional tolerances for perfect sealing between mating components
Chemical Compatibility: Resistant to water, hydraulic fluids, and common water treatment additives
Maintenance:
Failure Diagnosis:
External Water Leakage: Visible water weeping from the pump area or valve body indicates O-ring failure requiring immediate replacement
Pressure Drop: Inability to maintain rated cutting pressure may indicate seal degradation or extrusion
Physical Damage During Inspection: Replace immediately if the O-ring shows signs of nicks, cuts, flattening (compression set), fraying, misalignment, hardening, or cracking
Filter Gauge Reading: If the filter gauge approaches 25 psi or lower while the pump is running, inspect the filter housing O-ring
Inspection and Replacement Guidelines:
Single-Use Component: This O-ring is a consumable sealing element. Always replace with a new one whenever the associated pump component or valve assembly is disassembled. Do not reuse old O-rings
Preventive Replacement Schedule: For filter housing applications, inspect the O-ring periodically and replace every two years or immediately if leaking is detected
Inspection Frequency: High-pressure O-rings should be checked for wear every 20–50 operating hours
Clean Installation: Before installing a new O-ring, thoroughly clean the groove and mating surfaces with a soft cloth. Remove all debris, old seal residue, and mineral deposits
Lubrication: Apply a thin, uniform layer of manufacturer-recommended high-pressure grease to the O-ring during installation to prevent pinching, rolling, or tearing during assembly
Seating Verification: Ensure the O-ring is not twisted and is fully seated in its groove before reassembling mating components. You should see it nest inside the connector if installed correctly
Full Depressurization: Always fully depressurize the waterjet system (high-pressure water, hydraulic system, and air supply) and follow lockout/tagout procedures before disassembly
Torque Compliance: When reassembling, tighten all retaining components to the specific torque values listed in the equipment service manual to ensure proper O-ring compression without over-compression or damage
Use Appropriate Tools: Use a dental pick or needle nose pliers to remove damaged O-rings and push new ones into place
Storage: Store spare O-rings in a cool, dry environment (15–25°C, humidity <65%) away from direct sunlight, ozone sources, and chemicals to prevent premature aging
Cross-Reference Information:
OMAX #200905
Also known as URETHANE O-RING SIZE -018