A2260012-Standard-Sapphire-Orifice-0012-0305-mm.1078.3-1

Short Description:

The company is a world-leading manufacturer of high-pressure water jet pumps. 
The SL-VI 50HP pump is a highly classic and popular industrial high-pressure pump.
We offer original accessories and professional technical support.  


    
                  

Details

English Translation of Title:
Standard Sapphire Orifice 0.012–0.305 mm – Waterjet Cutting Equipment Accessory (ID: A2260012)

Description, Purpose, Features, and Maintenance:

This component is a precision synthetic sapphire orifice with a flow diameter ranging from 0.012 mm to 0.305 mm. It is installed at the waterjet cutting head, upstream of the abrasive mixing chamber, where it converts ultra‑high‑pressure water into a coherent, high‑velocity jet that entrains abrasive particles for cutting thick, dense, or hard‑to‑cut materials.

Purpose:

  • Restricts and accelerates water flow at pressures up to 6,000 bar to generate a stable, focused cutting stream.

  • Regulates water volume and jet diameter to suit heavy‑section materials and high‑feed‑rate operations.

  • Serves as the primary flow‑control element that determines jet coherence, abrasive mixing efficiency, and cutting precision.

Features:

  • Made from synthetic sapphire (single‑crystal aluminium oxide) for extreme hardness and outstanding wear resistance.

  • Precision‑machined bore ensures consistent flow characteristics and minimal jet divergence.

  • Chemically inert and fully corrosion‑resistant in high‑pressure water and abrasive slurry environments.

  • Maintains dimensional stability under extreme pressure cycling and temperature fluctuations.

  • Compact design enables rapid, tool‑free replacement in most cutting head configurations.

Maintenance:

  • Replace when cutting performance declines, evidenced by slower feed rates, wider kerf, rougher edges, or increased taper angle.

  • Inspect under magnification for erosion, cracking, or bore enlargement after every 80–120 operating hours.

  • Handle exclusively with non‑metallic tweezers; avoid finger contact to prevent contamination.

  • Clean using an ultrasonic bath with deionised water only; do not use abrasive cleaners or harsh solvents.

  • Install with the correct flow direction (marked on the component) to ensure proper jet formation.

  • Store spare units in a cushioned, dust‑tight container to protect against impact damage and particulate contamination.